Address: No. A25-1, Huading Mould Industrial Park, Hannan District, Wuhan, China
DC High Voltage Tester
Customized support: OEM, ODM, OBM
Place of Origin: Hubei, China
Brand Name: HMDQ
Model Number: HMZF
Prodct name: DC hipot test kit
Power supply: AC220V+10%, 50Hz+1%
Output voltage: 60KV/120KV/200KV/300KV
Output current: 2mA/3mA/5mA/10mA
Display: LCD Screen
DC HV generator is a technology product of new era, suitable for DC HV test and Dc leakage current test on zinc oxide arrester, magnetic blow-out arrester, power cable, generator, transformer, and switch in electric power department, scientific research unit, railway station, power plant, chemical plant, etc.,
* DC hipot tester, DC generator, DC test machine,DC high voltage test equipment, DC leakage current test set.
Technical Performance Specification and Working Methods
●DC Hipot tester which takes technique of APWM, enhancing degree of linearity of PWM and ripple factor is less than 0.5%, Improve instrument accuracy.
●Adopting AI technology screen to set over voltage protection and over current protection.
●Bring great convenience to measurement of zinc oxide arrester with the added function of high-accuracy 75%VDC-1mA; accuracy ≤0.5%.
●Add timer function under any voltage and any current, with total timing T1 and Segmented timing T2, it have Calendar and time function.
Technical Parameter
Specification
60/2/3
60/5
120/2/3/5
200/2/3
300/2/5
Technical Parameter
Output voltage((kV)
60
60
120
200
300
Output current (mA)
2/3
5
2/3/5
2/3
2/5
Output power (W)
120/180
400
240/360/600
400/600
600/1500
Charging current(mA)
3/4.5
5
3/4.5/6.5
3/4.5
3/7.5
Controller Case weight (kg)
10.1
13
13
13.1
13.1
Dimension of multi-voltage tube (mm)
Φ 90
Φ 110
Φ 90
Φ 110
Φ 110
× 380
× 530
× 470
× 910
× 1200
Height of multi-voltage tube (kg)
2.3
4
3.2
8.0
10
Voltage measuring accuracy
1.0%(full scale)± 1character, max resolution 0.1%kV
Current measuring accuracy
1.0%(full scale)± 1character, max resolution 0.1%uA
Over voltage rectify accuracy
≤ 1.0%
0.75 switch over accuracy
≤ 0.5%
Ripple factor
≤ 0.5%
Work manner
Intermittent service; 30min of rated load;
1.1 times of rated voltage use: 10min
Temperature
-10℃-50℃
Relative humidity
When at 25C, no more than 85%(no condensation)
Altitude
Below 1500m
Capacitance load
The capacitance of test object is no limit
Construction feature
Electric insulation multivoltage tube
Air insulation,no leakage
More specifications can be customized .
DC High Voltage Tester Wiring
Trouble Shooting
No.
Phenomena
Reasons
Resolutions
1
The red button not dark when power on.
1) Power cord open circuit.
2) Fuse broken.
1) Replace the power cord.
2) Replace the fuse.
2
Press green button, no light.
Potentiometer not return zero.
Counter clockwise potentiometer back to zero
3
Press green button, green light on, when boost, green light off, red light on.
1) Cylinder HV output terminal ground short circuit.
2) Tested equipment ground short circuit.
3) Over voltage setting wrong.
1) Check output HV cable.
2) Check tested equipment.
3) Resetting over voltage value.
4
Green light off and red light on when boosting.
The tested equipment discharged or broken-down, over voltage or over current protection.
1) Check the tested equipment
2) Reset the setting value
5
No display on the micro ammeter after it connected.
1) Low power of micro ammeter
2) Wire of micro ammeter broken.
Check the battery and wires.
6
The micro ammeter digit change larger
Micro ammeter low power
Replace the battery of the micro ammeter.
FAQ
1.What about leading time for production ?
Usually , it depends on our production situation and the required model’s specification . Usually lead time is within 7 working days after deposit,customized model should be negotiated again.
2.When can I get the price ?
The quotation can be provided within 6hours . If you are very urgent, pls email info@cablehipot.com, or call .
3.What is your terms of delivery ?
We accept EXW, FOB, CFR, CIF, DDU, DDP etc . You can choose the most convenient and cost effective terms for you .
4.How much is the shipping cost and logistic time ?
This is depend on the size and weight of your product, and the method of shipping ( by sea/ by ari/ by Express) and your designated port . Kindly afford us above information to check shipping cost and lostic time for you .
5.Can you provide the product calibration certificate?
Yes, we can issue our factory calibration certificate.
If you require the third-party calibration certificate, it also can be made,just if through the third party, it will be charged!